Beko Dishwasher Error Codes
Beko Dishwasher Error H2
Dishwasher turbidity sensor error
The turbidity sensor is the sensor in the sump that detects the presence of deterrgent
Beko Dishwasher Error H3
Dishwasher diverter valve position error
The diverter valve is the valve that controls the water flow to the either the top or bottom spray arms or to both at same time
Beko Dishwasher Error H4
NTC error
Dishwasher cannot read the temperature sensor
Beko Dishwasher Error H5
Uninterruptable water inlet error
What to do:
- Malfunction of Water-Inlet Valve (stuck as open)
- Malfunction of T7 triac on the electronic board
The electronic controller of the dishwasher monitors the water counter pulses during every step of the wash program. If the pulses received from the counter at any stage except when the dishwasher is supposed to be filling, and if the received pulses exceed 0.6 It. of water then this error will be displayed. When the fault detected, software drives the drain pump with 1 minute intervals (1 min ON, 1 min. OFF). During this interval if counter pulses stop (the dishwasher ceases to fill) then program will continue. Malfunction of Water-lnlet Valve (stuck as open). Malfunction of T7 triac on the electronic board
Beko Dishwasher Error H6
Water inlet fault
No water is detected
Beko Dishwasher Error H7
Heating fault Dishwasher doesn`t read heating
What to do:
- Check water heater
- Check wiring
- Check main module